hwmon: (lm95241) Use more accurate limits
The lower temperature limit is -128 degrees C. The supported upper limits are 127.875 or 255.875 degrees C. Also, don't fail if a value outside the supported range is provided when setting a temperature limit. Instead, clamp the provided value to the available value range. Signed-off-by: Guenter Roeck <linux@roeck-us.net>