summary refs log tree commit diff
path: root/drivers/power
diff options
context:
space:
mode:
authorChen-Yu Tsai <wens@csie.org>2019-04-16 14:40:19 +0800
committerSebastian Reichel <sebastian.reichel@collabora.com>2019-04-17 23:23:15 +0200
commitc11f0b8f226a411915f8d7467bd554a8c9ceec42 (patch)
tree0af45fbb71a5d05b4b93589e428e7289b45f043a /drivers/power
parent2e8c9d7bfab23419923e7ef52e53dd8cb288d9c4 (diff)
downloadlinux-c11f0b8f226a411915f8d7467bd554a8c9ceec42.tar.gz
power: supply: axp20x_usb_power: Fix typo in VBUS current limit macros
The VBUS current limit value macros have VBUS typed as VBUC, while
the bitmask macro is named correctly. Fix it.

Fixes: 69fb4dcada77 ("power: Add an axp20x-usb-power driver")
Signed-off-by: Chen-Yu Tsai <wens@csie.org>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
Diffstat (limited to 'drivers/power')
-rw-r--r--drivers/power/supply/axp20x_usb_power.c16
1 files changed, 8 insertions, 8 deletions
diff --git a/drivers/power/supply/axp20x_usb_power.c b/drivers/power/supply/axp20x_usb_power.c
index f52fe77edb6f..cd9b90d79839 100644
--- a/drivers/power/supply/axp20x_usb_power.c
+++ b/drivers/power/supply/axp20x_usb_power.c
@@ -36,10 +36,10 @@
 #define AXP20X_VBUS_VHOLD_MASK		GENMASK(5, 3)
 #define AXP20X_VBUS_VHOLD_OFFSET	3
 #define AXP20X_VBUS_CLIMIT_MASK		3
-#define AXP20X_VBUC_CLIMIT_900mA	0
-#define AXP20X_VBUC_CLIMIT_500mA	1
-#define AXP20X_VBUC_CLIMIT_100mA	2
-#define AXP20X_VBUC_CLIMIT_NONE		3
+#define AXP20X_VBUS_CLIMIT_900mA	0
+#define AXP20X_VBUS_CLIMIT_500mA	1
+#define AXP20X_VBUS_CLIMIT_100mA	2
+#define AXP20X_VBUS_CLIMIT_NONE		3
 
 #define AXP20X_ADC_EN1_VBUS_CURR	BIT(2)
 #define AXP20X_ADC_EN1_VBUS_VOLT	BIT(3)
@@ -107,19 +107,19 @@ static int axp20x_usb_power_get_property(struct power_supply *psy,
 			return ret;
 
 		switch (v & AXP20X_VBUS_CLIMIT_MASK) {
-		case AXP20X_VBUC_CLIMIT_100mA:
+		case AXP20X_VBUS_CLIMIT_100mA:
 			if (power->axp20x_id == AXP221_ID)
 				val->intval = -1; /* No 100mA limit */
 			else
 				val->intval = 100000;
 			break;
-		case AXP20X_VBUC_CLIMIT_500mA:
+		case AXP20X_VBUS_CLIMIT_500mA:
 			val->intval = 500000;
 			break;
-		case AXP20X_VBUC_CLIMIT_900mA:
+		case AXP20X_VBUS_CLIMIT_900mA:
 			val->intval = 900000;
 			break;
-		case AXP20X_VBUC_CLIMIT_NONE:
+		case AXP20X_VBUS_CLIMIT_NONE:
 			val->intval = -1;
 			break;
 		}