Pull thermal management updates from Zhang Rui:

 - Improve thermal cpu_cooling interaction with cpufreq core.

   The cpu_cooling driver is designed to use CPU frequency scaling to
   avoid high thermal states for a platform. But it wasn't glued really
   well with cpufreq core.

   For example clipped-cpus is copied from the policy structure and its
   much better to use the policy->cpus (or related_cpus) fields directly
   as they may have got updated. Not that things were broken before this
   series, but they can be optimized a bit more.

   This series tries to improve interactions between cpufreq core and
   cpu_cooling driver and does some fixes/cleanups to the cpu_cooling
   driver. (Viresh Kumar)

 - A couple of fixes and cleanups in thermal core and imx, hisilicon,
   bcm_2835, int340x thermal drivers. (Arvind Yadav, Dan Carpenter,
   Sumeet Pawnikar, Srinivas Pandruvada, Willy WOLFF)

* 'next' of git://git.kernel.org/pub/scm/linux/kernel/git/rzhang/linux: (24 commits)
  thermal: bcm2835: fix an error code in probe()
  thermal: hisilicon: Handle return value of clk_prepare_enable
  thermal: imx: Handle return value of clk_prepare_enable
  thermal: int340x: check for sensor when PTYP is missing
  Thermal/int340x: Fix few typos and kernel-doc style
  thermal: fix source code documentation for parameters
  thermal: cpu_cooling: Replace kmalloc with kmalloc_array
  thermal: cpu_cooling: Rearrange struct cpufreq_cooling_device
  thermal: cpu_cooling: 'freq' can't be zero in cpufreq_state2power()
  thermal: cpu_cooling: don't store cpu_dev in cpufreq_cdev
  thermal: cpu_cooling: get_level() can't fail
  thermal: cpu_cooling: create structure for idle time stats
  thermal: cpu_cooling: merge frequency and power tables
  thermal: cpu_cooling: get rid of 'allowed_cpus'
  thermal: cpu_cooling: OPPs are registered for all CPUs
  thermal: cpu_cooling: store cpufreq policy
  cpufreq: create cpufreq_table_count_valid_entries()
  thermal: cpu_cooling: use cpufreq_policy to register cooling device
  thermal: cpu_cooling: get rid of a variable in cpufreq_set_cur_state()
  thermal: cpu_cooling: remove cpufreq_cooling_get_level()
  ...
Diffstat (limited to 'drivers/cpufreq')
-rw-r--r--drivers/cpufreq/arm_big_little.c2
-rw-r--r--drivers/cpufreq/cpufreq-dt.c2
-rw-r--r--drivers/cpufreq/cpufreq_stats.c13
-rw-r--r--drivers/cpufreq/dbx500-cpufreq.c2
-rw-r--r--drivers/cpufreq/mt8173-cpufreq.c4
-rw-r--r--drivers/cpufreq/qoriq-cpufreq.c3
6 files changed, 9 insertions, 17 deletions
diff --git a/drivers/cpufreq/arm_big_little.c b/drivers/cpufreq/arm_big_little.c
index 418042201e6d..ea6d62547b10 100644
--- a/drivers/cpufreq/arm_big_little.c
+++ b/drivers/cpufreq/arm_big_little.c
@@ -540,7 +540,7 @@ static void bL_cpufreq_ready(struct cpufreq_policy *policy)
 				     &power_coefficient);
 
 		cdev[cur_cluster] = of_cpufreq_power_cooling_register(np,
-				policy->related_cpus, power_coefficient, NULL);
+				policy, power_coefficient, NULL);
 		if (IS_ERR(cdev[cur_cluster])) {
 			dev_err(cpu_dev,
 				"running cpufreq without cooling device: %ld\n",
diff --git a/drivers/cpufreq/cpufreq-dt.c b/drivers/cpufreq/cpufreq-dt.c
index c943787d761e..fef3c2160691 100644
--- a/drivers/cpufreq/cpufreq-dt.c
+++ b/drivers/cpufreq/cpufreq-dt.c
@@ -326,7 +326,7 @@ static void cpufreq_ready(struct cpufreq_policy *policy)
 				     &power_coefficient);
 
 		priv->cdev = of_cpufreq_power_cooling_register(np,
-				policy->related_cpus, power_coefficient, NULL);
+				policy, power_coefficient, NULL);
 		if (IS_ERR(priv->cdev)) {
 			dev_err(priv->cpu_dev,
 				"running cpufreq without cooling device: %ld\n",
diff --git a/drivers/cpufreq/cpufreq_stats.c b/drivers/cpufreq/cpufreq_stats.c
index d362739a71f3..e75880eb037d 100644
--- a/drivers/cpufreq/cpufreq_stats.c
+++ b/drivers/cpufreq/cpufreq_stats.c
@@ -170,11 +170,10 @@ void cpufreq_stats_create_table(struct cpufreq_policy *policy)
 	unsigned int i = 0, count = 0, ret = -ENOMEM;
 	struct cpufreq_stats *stats;
 	unsigned int alloc_size;
-	struct cpufreq_frequency_table *pos, *table;
+	struct cpufreq_frequency_table *pos;
 
-	/* We need cpufreq table for creating stats table */
-	table = policy->freq_table;
-	if (unlikely(!table))
+	count = cpufreq_table_count_valid_entries(policy);
+	if (!count)
 		return;
 
 	/* stats already initialized */
@@ -185,10 +184,6 @@ void cpufreq_stats_create_table(struct cpufreq_policy *policy)
 	if (!stats)
 		return;
 
-	/* Find total allocation size */
-	cpufreq_for_each_valid_entry(pos, table)
-		count++;
-
 	alloc_size = count * sizeof(int) + count * sizeof(u64);
 
 	alloc_size += count * count * sizeof(int);
@@ -205,7 +200,7 @@ void cpufreq_stats_create_table(struct cpufreq_policy *policy)
 	stats->max_state = count;
 
 	/* Find valid-unique entries */
-	cpufreq_for_each_valid_entry(pos, table)
+	cpufreq_for_each_valid_entry(pos, policy->freq_table)
 		if (freq_table_get_index(stats, pos->frequency) == -1)
 			stats->freq_table[i++] = pos->frequency;
 
diff --git a/drivers/cpufreq/dbx500-cpufreq.c b/drivers/cpufreq/dbx500-cpufreq.c
index 3575b82210ba..4ee0431579c1 100644
--- a/drivers/cpufreq/dbx500-cpufreq.c
+++ b/drivers/cpufreq/dbx500-cpufreq.c
@@ -43,7 +43,7 @@ static int dbx500_cpufreq_exit(struct cpufreq_policy *policy)
 
 static void dbx500_cpufreq_ready(struct cpufreq_policy *policy)
 {
-	cdev = cpufreq_cooling_register(policy->cpus);
+	cdev = cpufreq_cooling_register(policy);
 	if (IS_ERR(cdev))
 		pr_err("Failed to register cooling device %ld\n", PTR_ERR(cdev));
 	else
diff --git a/drivers/cpufreq/mt8173-cpufreq.c b/drivers/cpufreq/mt8173-cpufreq.c
index fd1886faf33a..f9f00fb4bc3a 100644
--- a/drivers/cpufreq/mt8173-cpufreq.c
+++ b/drivers/cpufreq/mt8173-cpufreq.c
@@ -320,9 +320,7 @@ static void mtk_cpufreq_ready(struct cpufreq_policy *policy)
 		of_property_read_u32(np, DYNAMIC_POWER, &capacitance);
 
 		info->cdev = of_cpufreq_power_cooling_register(np,
-						policy->related_cpus,
-						capacitance,
-						NULL);
+						policy, capacitance, NULL);
 
 		if (IS_ERR(info->cdev)) {
 			dev_err(info->cpu_dev,
diff --git a/drivers/cpufreq/qoriq-cpufreq.c b/drivers/cpufreq/qoriq-cpufreq.c
index e2ea433a5f9c..4ada55b8856e 100644
--- a/drivers/cpufreq/qoriq-cpufreq.c
+++ b/drivers/cpufreq/qoriq-cpufreq.c
@@ -278,8 +278,7 @@ static void qoriq_cpufreq_ready(struct cpufreq_policy *policy)
 	struct device_node *np = of_get_cpu_node(policy->cpu, NULL);
 
 	if (of_find_property(np, "#cooling-cells", NULL)) {
-		cpud->cdev = of_cpufreq_cooling_register(np,
-							 policy->related_cpus);
+		cpud->cdev = of_cpufreq_cooling_register(np, policy);
 
 		if (IS_ERR(cpud->cdev) && PTR_ERR(cpud->cdev) != -ENOSYS) {
 			pr_err("cpu%d is not running as cooling device: %ld\n",