Merge branch 'release' of git://git.kernel.org/pub/scm/linux/kernel/git/rzhang/linux into thermal
Conflicts:
	drivers/staging/omap-thermal/omap-thermal-common.
		OMAP supplied dummy TC1 and TC2,
		at the same time that the thermal tree removed them
		from thermal_zone_device_register()

	drivers/thermal/cpu_cooling.c b/drivers/thermal/cpu_cooling.c
		propogate the upstream MAX_IDR_LEVEL re-name
			to prevent a build failure

	Previously-fixed-by: Stephen Rothwell <sfr@canb.auug.org.au>

Signed-off-by: Len Brown <len.brown@intel.com>
Diffstat (limited to 'Documentation')
-rw-r--r--Documentation/thermal/cpu-cooling-api.txt32
-rw-r--r--Documentation/thermal/exynos_thermal (renamed from Documentation/hwmon/exynos4_tmu)35
-rw-r--r--Documentation/thermal/sysfs-api.txt9
3 files changed, 43 insertions, 33 deletions
diff --git a/Documentation/thermal/cpu-cooling-api.txt b/Documentation/thermal/cpu-cooling-api.txt
new file mode 100644
index 000000000000..fca24c931ec8
--- /dev/null
+++ b/Documentation/thermal/cpu-cooling-api.txt
@@ -0,0 +1,32 @@
+CPU cooling APIs How To
+===================================
+
+Written by Amit Daniel Kachhap <amit.kachhap@linaro.org>
+
+Updated: 12 May 2012
+
+Copyright (c)  2012 Samsung Electronics Co., Ltd(http://www.samsung.com)
+
+0. Introduction
+
+The generic cpu cooling(freq clipping) provides registration/unregistration APIs
+to the caller. The binding of the cooling devices to the trip point is left for
+the user. The registration APIs returns the cooling device pointer.
+
+1. cpu cooling APIs
+
+1.1 cpufreq registration/unregistration APIs
+1.1.1 struct thermal_cooling_device *cpufreq_cooling_register(
+	struct cpumask *clip_cpus)
+
+    This interface function registers the cpufreq cooling device with the name
+    "thermal-cpufreq-%x". This api can support multiple instances of cpufreq
+    cooling devices.
+
+   clip_cpus: cpumask of cpus where the frequency constraints will happen.
+
+1.1.2 void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev)
+
+    This interface function unregisters the "thermal-cpufreq-%x" cooling device.
+
+    cdev: Cooling device pointer which has to be unregistered.
diff --git a/Documentation/hwmon/exynos4_tmu b/Documentation/thermal/exynos_thermal
index c3c6b41db607..2b46f67b1ccb 100644
--- a/Documentation/hwmon/exynos4_tmu
+++ b/Documentation/thermal/exynos_thermal
@@ -46,36 +46,7 @@ The threshold levels are defined as follows:
   The threshold and each trigger_level are set
   through the corresponding registers.
 
-When an interrupt occurs, this driver notify user space of
-one of four threshold levels for the interrupt
-through kobject_uevent_env and sysfs_notify functions.
+When an interrupt occurs, this driver notify kernel thermal framework
+with the function exynos4_report_trigger.
 Although an interrupt condition for level_0 can be set,
-it is not notified to user space through sysfs_notify function.
-
-Sysfs Interface
----------------
-name		name of the temperature sensor
-		RO
-
-temp1_input	temperature
-		RO
-
-temp1_max	temperature for level_1 interrupt
-		RO
-
-temp1_crit	temperature for level_2 interrupt
-		RO
-
-temp1_emergency	temperature for level_3 interrupt
-		RO
-
-temp1_max_alarm	alarm for level_1 interrupt
-		RO
-
-temp1_crit_alarm
-		alarm for level_2 interrupt
-		RO
-
-temp1_emergency_alarm
-		alarm for level_3 interrupt
-		RO
+it can be used to synchronize the cooling action.
diff --git a/Documentation/thermal/sysfs-api.txt b/Documentation/thermal/sysfs-api.txt
index c087dbcf3535..ca1a1a34970e 100644
--- a/Documentation/thermal/sysfs-api.txt
+++ b/Documentation/thermal/sysfs-api.txt
@@ -84,7 +84,8 @@ temperature) and throttle appropriate devices.
 
 1.3 interface for binding a thermal zone device with a thermal cooling device
 1.3.1 int thermal_zone_bind_cooling_device(struct thermal_zone_device *tz,
-		int trip, struct thermal_cooling_device *cdev);
+	int trip, struct thermal_cooling_device *cdev,
+	unsigned long upper, unsigned long lower);
 
     This interface function bind a thermal cooling device to the certain trip
     point of a thermal zone device.
@@ -93,6 +94,12 @@ temperature) and throttle appropriate devices.
     cdev: thermal cooling device
     trip: indicates which trip point the cooling devices is associated with
 	  in this thermal zone.
+    upper:the Maximum cooling state for this trip point.
+          THERMAL_NO_LIMIT means no upper limit,
+	  and the cooling device can be in max_state.
+    lower:the Minimum cooling state can be used for this trip point.
+          THERMAL_NO_LIMIT means no lower limit,
+	  and the cooling device can be in cooling state 0.
 
 1.3.2 int thermal_zone_unbind_cooling_device(struct thermal_zone_device *tz,
 		int trip, struct thermal_cooling_device *cdev);