summary refs log tree commit diff
path: root/Documentation/hwmon/sysfs-interface
diff options
context:
space:
mode:
authorGuenter Roeck <guenter.roeck@ericsson.com>2010-08-14 21:08:52 +0200
committerJean Delvare <khali@linux-fr.org>2010-08-14 21:08:52 +0200
commitf46fc8cd382f318a7d9c6cd0af1b771c74e5dfd0 (patch)
tree3ec6a8c0310d7532cb59f9c9efbbeab427f069b6 /Documentation/hwmon/sysfs-interface
parent28cbd461f022e30dba555926b76625a35e194166 (diff)
downloadlinux-f46fc8cd382f318a7d9c6cd0af1b771c74e5dfd0.tar.gz
hwmon: Add 3 critical limit attributes to sysfs-interface
Added _lcrit and _crit to voltage attributes. 
Added _lcrit to temperature attributes.

Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Signed-off-by: Jean Delvare <khali@linux-fr.org>
Diffstat (limited to 'Documentation/hwmon/sysfs-interface')
-rw-r--r--Documentation/hwmon/sysfs-interface21
1 files changed, 20 insertions, 1 deletions
diff --git a/Documentation/hwmon/sysfs-interface b/Documentation/hwmon/sysfs-interface
index d4e2917c6f18..2e492187a665 100644
--- a/Documentation/hwmon/sysfs-interface
+++ b/Documentation/hwmon/sysfs-interface
@@ -107,10 +107,24 @@ in[0-*]_min	Voltage min value.
 		Unit: millivolt
 		RW
 		
+in[0-*]_lcrit	Voltage critical min value.
+		Unit: millivolt
+		RW
+		If voltage drops to or below this limit, the system may
+		take drastic action such as power down or reset. At the very
+		least, it should report a fault.
+
 in[0-*]_max	Voltage max value.
 		Unit: millivolt
 		RW
 		
+in[0-*]_crit	Voltage critical max value.
+		Unit: millivolt
+		RW
+		If voltage reaches or exceeds this limit, the system may
+		take drastic action such as power down or reset. At the very
+		least, it should report a fault.
+
 in[0-*]_input	Voltage input value.
 		Unit: millivolt
 		RO
@@ -284,7 +298,7 @@ temp[1-*]_input Temperature input value.
 		Unit: millidegree Celsius
 		RO
 
-temp[1-*]_crit	Temperature critical value, typically greater than
+temp[1-*]_crit	Temperature critical max value, typically greater than
 		corresponding temp_max values.
 		Unit: millidegree Celsius
 		RW
@@ -296,6 +310,11 @@ temp[1-*]_crit_hyst
 		from the critical value.
 		RW
 
+temp[1-*]_lcrit	Temperature critical min value, typically lower than
+		corresponding temp_min values.
+		Unit: millidegree Celsius
+		RW
+
 temp[1-*]_offset
 		Temperature offset which is added to the temperature reading
 		by the chip.